Skip to content

UPS Service

If your server is battery-backed, this service handles the graceful shutdown of your DCS servers and your PC in case of a power failure.

Configuration

The configuration file for this service has to be placed into config\services\ups.yaml:

# config/services/ups.yaml
DEFAULT:
  device: nutdev1       # UPS device name
  host: 192.168.178.123 # UPS host (the host running the NUT server)
  port: 3493            # Optional: NUT port (default: 3493)
  username: xxxx        # Optional: the user credentials to log in to the NUT server.
  password: xxxx        # Optional: the user credentials to log in to the NUT server.
  thresholds:
    warn: 90            # warn users
    shutdown: 50        # shutdown DCS
    halt: 20            # shutdown PC

To configure the DCS server monitoring, you can change these values in your nodes.yaml and scheduler.yaml:

nodes.yaml

# config/nodes.yaml
MyNode:
  DCS.dcs_serverrelease:
    max_hung_minutes: 5   # maximum heartbeats a server can miss (default: 3)

plugins/scheduler.yaml

# config/plugins/scheduler.yaml
DCS.dcs_serverrelease:
  schedule:
    00-24: YYYYYYY  # the server (and its DCS_server.exe process) should run 24x7

Configuration reference

Key Type Description Example
DEFAULT map Applies to every instance.

DEFAULT

Key Type Description Example
DEFAULT.device str Name of the UPS device on the NUT server. (range: min 1) nutdev1
DEFAULT.host str IP address of the host that runs the NUT server. 192.168.178.123
DEFAULT.port int Port of the NUT server. 3493
DEFAULT.username str User to log in to the NUT server (optional). (range: min 1) upsuser
DEFAULT.password str Password to log in to the NUT server (optional). (range: min 1) secret
DEFAULT.thresholds map Remaining battery percentage that triggers each action. warn: 90
shutdown: 50
halt: 20
DEFAULT.thresholds.warn int Battery level (%) that warns the players. (range: min 1, max 100) 90
DEFAULT.thresholds.shutdown int Battery level (%) that shuts down the DCS servers. (range: min 1, max 100) 50
DEFAULT.thresholds.halt int Battery level (%) that shuts down the whole PC. (range: min 1, max 100) 20

<(.+)>

Key Type Description Example